WXP version 5
User's Guide

Meteorological Computations

The Weather Processor contains several programs to perform often-used meteorological and non-meteorological calculations. These programs take input from the keyboard and display the results in a tabular form on the display.

Sunrise Sunset Computation

The suncalc program is used to compute sunrise, sunset and twilight.  The input to the program is a location that can be a station identifier or latitude and longitude.  The second input is the date.   This can either be:

Unit Conversions

The unit program is used to convert units.  This uses the WXP unit interface.  The input is a value, its units and the desired units.

unit 25 C F
77.000000 

Domain Computation

The domtran program is used to convert between various domain values.  There are three coordinate systems used:

domtran -pd=us earth2proj 40,-90
6.755947,-55.022774        
domtran -pd=us earth2grid 40,-90
14.937368,7.268939                       

Wind Chill Computation

The wchill program calculates wind chill factors. The wind chill program first displays a wind chill chart for quick reference and then prompts the user for temperature and wind speed. From this information, the wind chill factor is calculated. The wind chill factor is relatively meaningless for a temperature greater than 50F because the wind cools the skin's surface less for warmer temperatures. Also, the wind chill factor changes little for wind speeds greater than 40 miles per hour. At these speeds, the wind removes nearly all heat produced at the skin's surface.

Heat Index Computation

The heat program first displays a heat index chart for quick reference and then prompts the user for temperature and dewpoint. From this information, the heat index is calculated. The heat index is relatively meaningless for temperatures less than 65F, since below this temperature, the skin loses more heat than is produced. Also, the heat index is meaningless for dewpoints less than 65F, since the drier air leads to evaporative cooling of the skin's surface. A second index called the temperature-humidity index is calculated for comparison and a textual heat stress condition such as normal, low, medium, high or extreme based on the temperature-humidity index is displayed.

Moisture Parameter Computation

The moist program derives various moisture variables given three of the four variables: temperature, dewpoint, and station pressure or station elevation. The information displayed includes wetbulb temperature, vapor pressure, saturation vapor pressure, relative humidity, specific humidity, mixing ratio, saturation mixing ratio and equivalent potential temperature.

Standard Atmosphere Computation

The stdatms program relates pressure, height and temperature. Information is provided for height or pressure in one of the following units:

The program then calculates the height, pressure and temperature (in various units) at that specific level for a standard atmosphere.


Last updated June 7, 1998